KSh 1,500.00

Early fire detection for offices, shops and homes. This conventional photoelectric smoke detector detects smoke from slow burning fires instantly. Works with any conventional fire alarm panel – 2 zone, 4 zone, 8 zone. With LED alarm indicator and 360 degree detection. EN54 certified.

Description

Conventional Photoelectric Smoke Detector – 24V For Fire Alarm System.

Detect Fire Before It Spreads

The Conventional Smoke Detector is the most important device in your fire alarm system. It detects smoke in less than 5 seconds and sends signal to your fire alarm control panel to ring the alarm bells.

This is a photoelectric type detector – best for detecting smoke from slow smouldering fires like burning wood, paper, fabric and plastic. This is the type of fire that happens in offices, shops and homes.

It is not like heat detectors that wait for high temperature. Smoke detector gives you early warning to evacuate and save stock and lives.

Compatible with all conventional panels including C-TEC, Kentec, Honeywell, Zeta and generic 2 zone, 4 zone and 8 zone panels.

Why Contractors Prefer This Model:
Non polarity wiring, wide voltage range 9V to 28V, and removable detector head for easy cleaning. One person can install and test it in 5 minutes.

Key Features

  • Early Detection: Photoelectric sensor detects visible smoke from smouldering fires
  • Universal Compatibility: Works with any conventional 2 zone, 4 zone, 8 zone fire panel
  • 360 Degree Detection: Detects smoke from any direction, no blind spot
  • LED Indicator: Red LED flashes every 6 seconds in standby, solid red in fire alarm
  • Easy Install: 2 wire, non polarity, plug in base with twist lock
  • Removable Chamber: Easy to clean and maintain, reduces false alarms
  • Wide Voltage: 9V to 28V DC, low power 35uA standby
  • Certified: EN54-7 certified, CE marked, approved for commercial use.

Where To Use

Required by fire safety law for:
Offices, Shops, Supermarkets, Schools, Restaurants, Hospitals, Apartments, Warehouses, Kitchens with extra heat detector, Server Rooms use with extra heat detector.

Spacing Rule: Install one detector every 7 to 9 meters, or one per 60 sq meters.

Q: How many smoke detectors per zone?
A: Up to 32 conventional smoke detectors per zone on a 4 zone panel.

Q: Is it compatible with my 2 zone panel?
A: Yes, it works with any conventional panel – 2 zone, 4 zone, 8 zone, any brand.

Q: What is difference between conventional and addressable smoke detector?
A: Conventional works by zone. Addressable gives exact detector number. Conventional is cheaper and best for small buildings.

Q: Does it need battery?
A: No, it gets 24V power from fire alarm control panel.

Buy more save more: . Same day delivery Nairobi. We also have heat detectors and manual call points